Issue |
ITM Web Conf.
Volume 26, 2019
2018 International Conference on Computer Science and Education Technology (CSET 2018)
|
|
---|---|---|
Article Number | 02003 | |
Number of page(s) | 4 | |
Section | Information Science and Biomedical Science | |
DOI | https://doi.org/10.1051/itmconf/20192602003 | |
Published online | 04 February 2019 |
CT and MRI Imaging Features and Grades of Liver Iron Deposition
Zhongshan Hospital of Xiamen University, 209 South Hubin Rd., Xiamen, 361004, China
a Corresponding author: xmdsy@xmu.edu.cn
CT and MRI imaging features and grades of liver iron deposition(LID)were discussed and evaluated in clinical application.The imaging and laboratory data of 20 patients with LID were analyzed retrospectively. CT value of liver were measured and MR signal intensity ratio of muscle/liver calculated.A new imaging grade of LID were made with CT and MR, and the grade correlation was analyzed between CT, MR and SF. All of 20 patients with LID, 19 cases were CT examination, their CT value ranging of liver were from 55HU to 116HU, of which more than 72HU were in 7 cases and 72HU or less in 12. 14 cases were MR examination with the low signal of liver, and the inverse phase signal of T1WI was higher than that of the positive phase. There were no significant difference among the grade of CT, T1WI, T2WI and SF (P>0.05), and there were the positive correlation of grade between CT, T1WI, T2WI and SF (rs=0.803,0.847,0.677 respectively), and of values between CT, T1WI SIR, T2WI SIR and SF(rs=0.454, 0.538, 0.811 respectively). CT can show the LID with high-density, but the mild LID can be with normal density, which is the false negative. MRI can show LID with low-signal, of which T2WI is the lower than T1WI, it is beneficial to diagnose the early LID. Grades of CT and MR have good consistent with that of SF, and can reflect the severity of LID, particularly that of MR-T1WI grading.
© The Authors, published by EDP Sciences, 2019
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.